Cooling strategies for floating data centers

Air, water and liquid cooling options for floating data centers, and why sea-water cooling depends on temperature, depth, fouling and environmental permits.

6 min read

Every watt of electricity that goes into IT equipment comes out as heat. On land, that heat is usually rejected to the air through chillers, dry coolers or cooling towers. A floating data center has the same options plus one more: the water it floats in.

Rejecting heat to air

Dry coolers and air-cooled chillers on deck or on module roofs work the same way as on land. They need space, add weight high up on the platform, and must be protected from salt-laden air. Their performance falls as ambient air temperature rises, so summer conditions at the berth set the design point.

Rejecting heat to water

Water absorbs heat far better than air, which is why sea, river or lake water cooling is attractive. A typical arrangement keeps the data center's own coolant in a closed loop and transfers heat to surrounding water through a heat exchanger. Key questions:

  • Water temperature through the year, at the depth where water would be drawn.
  • Depth and water exchange at the berth, which affect how quickly warmed water disperses.
  • Biofouling, corrosion and debris, which reduce heat exchanger performance and need cleaning or treatment.
  • Discharge permits. Regulators may limit the temperature rise of returned water or the volume drawn, to protect marine life.

Because of the last point, sea-water cooling is never assumed. It is assessed site by site, and an air-based fallback may be needed.

Liquid cooling for high-density loads

AI and high-performance computing racks can draw far more power than conventional racks, and air alone struggles to remove that heat. Direct-to-chip liquid cooling and immersion cooling move heat into a liquid at the rack. On a floating platform this can be a good match with water-side heat rejection, since the heat is already in a liquid loop. It also changes weight, piping and maintenance requirements and has to be decided early.

Designing the thermal chain

We treat cooling as a chain from chip to environment: rack, room or module, plant, heat rejection. A choice at one end constrains the others. That is why the intended IT load and rack density are among the first things we ask a client for, even as a rough range.

What to expect from an assessment

A cooling assessment for a floating concept typically produces a recommended architecture, the assumptions it relies on, the permits it would need and the main risks. It does not produce a guaranteed efficiency figure until site data and equipment are confirmed.